Precautions Prior Starting A Boiler

Contact Us

Product thermal capacity: 0.7 - 14 MW

Working pressure: 0.7 - 1.25 Mpa

Available fuel: Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.

Available industries: Heat supplying, hospital, hotel.

Introduction

WNS series horizontal internal combustion boiler is classic 3-pass wetback oil/gas fired boiler. After fuel is atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, called 1st pass; the high temperature flue gasses are collected in reversal chamber and then enter 2nd pass, which is grooved tube bundle area through heat convection, air temperature gradually falls and flows to front smoke box and enter 3rd pass, which is done in the smooth tube bundle area, and then through back smoke box lead to chimney and exhausted to the atmosphere.

Technical Advantages

Digitized Manufacture

The key processes including material cutting, rolling, drilling are made by advanced CNC machining process to reduce the assembly stress and extend boiler working lifetime.
The front and back smoke chamber plates are cut by CNC plasma cutting machine with tidy and beautiful look.

Easy Operation and Maintenance

Fully intelligent operation, with automatic adjustment and protection of burning, water level, temperature and steam pressure. The smoke box door uses the hinge structure for easy inspection, inventory and cleaning.

Long Service Life

The way to weld Smoke tube and tube sheet is to first expand to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boiler service life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint are test by radiographic inspection.
Fin tube uses ND steel or stainless-steel material to avoid corrosion in the low temperature.
Inspection stops are set up to guarantee the sequence of expanding and welding to avoid cracking of the tube sheet holes.

Less Fuel Consumption

High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ and reduce heat lost.
Sufficient steam storage room and heating area to generate high quality steam and high thermal power.
Condenser is added to recycle the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce flue gas emission temperature and increase the thermal efficiency over 98% and save operating cost.

Factory owners must ensure the boiler

2017-12-19 · boiler and may cause boiler explosion with consequent injuries to personnel. * All automatic safety devices such as safety valve, pressure switch and low-water cut-off switches should be tested periodically to ensure they are in good working condition at all times. * If accident happens to a boiler or its auxiliary, owner must immediately stop

How to Inspect and Start Your Gas Furnace | DI

How to Inspect and Start Your Gas Furnace. The cool and refreshing breeze of Fall is in the air and many of us will be turning the thermostat to the heat setting and starting up the gas furnace for the first time in 5 months or longer! I haven't run the gas furnaces that heat my home since March or April clearly enough time for spiders, birds, or any other small critters to find their way

Prep Solution 102™ - Wood Boiler Solutions L

Carefully mix Prep Solution 102™ in a clean 5 gallon bucket with 2-3 gallons of warm, clean water. Refill boiler with fresh water adding entire contents of your Prep Solution 102™ mixture directly to boiler. Fire your boiler to warm system water to assist product effectiveness and circulate for 4-12 hours. Completely drain and flush system.

unit14_boiler_mounting,managemnent_an

2013-11-1 · facilitate subsequent starting from cold, the fuel system of large boilers will have been flushed through with diesel oil when the boiler was on light duty immediately prior to being secured (). When burning such diesel fuel it is essential for safety that

(Safet

2017-7-15 · (Safety precautions during installation and commissioning of electrical equipment).doc 7 : ,

Are boilers dangerous? | 2013-09-20 | Plumbing an

Are boilers dangerous? Take precautions when repairing or maintaining commercial boilers. I was starting a new boiler and the installer had wired the gas valve to the line voltage terminal by mistake and I missed it. I opened the manual gas valve and the boiler filled with natural gas during the 90-second prepurge. the person who worked

Industrial Process Pump Safety Manual - Goulds Pum

2012-8-30 · Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds pumps will provide safe, trouble-free service when properly installed, maintained, and operated.

CLEAN BURN COIL TUBE BOILER MODE

2018-6-6 · precautions are not taken. In addition to observing the specific precautions listed throughout the manual, the following general precautions apply and must be heeded to ensure proper, safe boiler operation. DANGER! DO NOT create a fire or explosion hazard by storing or using gasoline or other flammable or explosive liquids or vapors near your

The Safety Precautions in Handling of Autoclave-ZB

2019-4-8 · The Safety Precautions in Handling of Autoclave 2018-05-30 Industrial autoclaves are widely used in aerated concrete block, concrete pipe pile, high curing gypsum and other building materials, as well as rubber products, wood drying, preservative treatment and other production projects that require pressure steam curing.

FIREMAN BOILER OPERATOR SYLLABUS - tsask.

2018-7-25 · Be prepared to provide picture ID to the Examiner prior to the examination. Explain the preparation required before starting up a boiler. b) Explain the procedure for starting up and shutting down a boiler. c) Explain the precautions necessary to prevent uneven expansion and thermal shock. d) Describe how to cut in an additional boiler.

procedure in starting of water tube boil

The burner must therefore only be operated at minimum load and in intervals of 1-2 minutes for the first hours. Between each operation interval the burner should remain stopped for approximately 8-10 minutes. The article explains starting and stopping boiler during normal and emergency working conditions. Precautions on Starting Boiler. Learn More